Single Cone Tensile Structure Specification

  • Wall Materials
  • Not Applicable (Open Structure)
  • Dimension (L*W*H)
  • Customizable, e.g. 6m (Dia) x 3.5m (H)
  • Insulation
  • Optional (Thermal or Acoustic Lining on Request)
  • Open Style
  • Open Sides / Free Standing
  • Life Span
  • 15-20 Years (Roof Membrane)
  • Connection
  • Steel Base Plate With Bolts and Fixings
  • Material
  • Mild Steel/ Galvanized Steel frame with Tensile Fabric Membrane
  • Roof Material
  • PVC Coated Polyester Fabric (High-Tensile Membrane)
  • Door
  • No
  • Window
  • No
  • Floor Material
  • Concrete or Paver Blocks
  • Floor Load
  • Designed up to 300 kg/m2 (customizable)
  • Roof Dead Load
  • 15-25 kg/m2
  • Roof Live Load
  • 80-120 kg/m2
  • Earthquake Intensity
  • Up to Seismic Zone IV
  • Color
  • White (Custom colors available)
  • Use
  • Outdoor Canopy, Walkway, Shade, Gazebo, Outdoor Sitting Area
  • Maintenance
  • Low, periodic cleaning of membrane recommended
  • Installation Time
  • 1-2 weeks depending on site conditions
  • Shape
  • Single Cone (Central Mast Supported)
  • UV Resistance
  • Yes (membrane provides UV protection)
  • Fire Retardancy
  • Yes (membrane is flame retardant as per international standards)
  • Fabric Weight
  • 700-950 gsm
  • Structural Frame Coating
  • Hot Dip Galvanized or Powder Coated
  • Wind Resistance
  • Up to 120 km/h
  • Application Areas
  • Resorts, Hotels, Airports, Parks, Cafeterias, Pool Sides, Exhibition Spaces
 

Single Cone Tensile Structure Trade Information

  • Minimum Order Quantity
  • 100 Square Feet
  • Payment Terms
  • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash in Advance (CID)
  • Supply Ability
  • 1000 Per Month
  • Delivery Time
  • 7-14 Days
  • Main Domestic Market
  • All India
 

About Single Cone Tensile Structure



Find excellence with our Single Cone Tensile Structure, featuring a flawless design supported by a venerable central mast. Select from a hot dip galvanized or powder-coated structural frame, complemented by a high-tensile, UV-resistant, and fire-retardant membrane (700-950 gsm) for stellar durability. Engineered for wind resistance up to 120 km/h and seismic zone IV, this canopy suits resorts, hotels, airports, and more. Customizable dimensions, a 15-20 year roof life span, and low maintenance make it the featured choice for sophisticated outdoor spaces across India.

Specialized and General Applications of Single Cone Tensile Structure

The Single Cone Tensile Structure is ideally suited for both specialized and broad applications such as walkways, gazebos, outdoor canopies, and shaded sitting areas. Direction of use involves installing the structure on concrete or paver block floors, ensuring appropriate anchoring for safety and durability. Its plant applications extend to resorts, airports, hotels, restaurants, and exhibition spaces, blending practicality and aesthetic appeal to deliver functional, attractive coverage for various environments.


Packaging, Shipment, and Payment Terms for Delivery

Each Single Cone Tensile Structure is meticulously packaged for shipment to prevent damage during transit. Customers can expect drop-off and delivery at designated sites within the committed time frame. Shipment is supported by flexible payment terms tailored for convenience and assurance. Benefit from a steady supply ability, ensuring your orders are delivered promptly, regardless of size or location, making the installation process streamlined and efficient.


FAQ's of Single Cone Tensile Structure:


Q: How is the Single Cone Tensile Structure installed?

A: The structure is installed by anchoring the central mast to a prepared concrete or paver block base using a steel base plate with bolts and fixings. Installation typically takes 1-2 weeks depending on site conditions.

Q: What maintenance does this tensile structure require?

A: Maintenance is minimal, primarily requiring periodic cleaning of the membrane to maintain its flawless appearance and ensure long-term performance.

Q: When is the ideal time to choose this structure for my project?

A: The Single Cone Tensile Structure is best selected during the planning phase of outdoor projects needing reliable, contemporary shade solutions for resorts, hotels, parks, or event spaces.

Q: Where can this product be most effectively utilized?

A: This structure is effective in both commercial and recreational spaces such as pool sides, open cafeterias, airports, parks, and exhibition areas.

Q: What are the main benefits of the hot dip galvanized or powder-coated frame?

A: Both finishes deliver stellar corrosion resistance and durability, ensuring a long lifespan and minimizing maintenance, even in challenging outdoor conditions.

Q: How customizable are the dimensions and colors of this canopy?

A: Dimensions and fabric colors are fully customizable to fit your specific architectural needs and design preferences, providing seamless integration into your space.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Prefabricated Structure Category

Tensile Structure

Tensile Structure

Minimum Order Quantity : 100

Floor Material : Concrete/Customized

Connection : Steel Structure, Bolted Joint

Life Span : 1525 years

Open Style : Other, Open / Customizable

Roof Live Load : As per local standard

Tensile Gazebo Parking

Tensile Gazebo Parking

Minimum Order Quantity : 100

Floor Material : Concrete or Pavers

Connection : Bolted & Welded Steel Frames

Life Span : 1520 years (depends on material used)

Open Style : Other, Open/Gazebo Style

Roof Live Load : Designed for typical wind & rain loading standards

PVC Tensile Canopy Structures

PVC Tensile Canopy Structures

Minimum Order Quantity : 100

Floor Material : Not Applicable (Typically Installed Over Existing Surface)

Connection : Steel Framework with HighStrength Bolted/Tensioned Connections

Life Span : 1525 Years (Depending on Fabric and Maintenance)

Open Style : Other, Open/Sideless

Roof Live Load : Upto 120 kg/m2 (Depends on Local Codes and Usage)

Car Parking Tensile Shed

Car Parking Tensile Shed

Minimum Order Quantity : 100

Floor Material : Concrete or Paver Blocks

Connection : Bolted/Anchored steel frame connections

Life Span : 15+ years

Open Style : Other, Open

Roof Live Load : Designed for standard wind and rain load



arrow